home *** CD-ROM | disk | FTP | other *** search
- SETUP1.TXT File for Setup Toolkit SETUP1.BAS and SETUP1.FRM
- -----------------------------------------------------------
-
- This file lists the changes made to files in the SETUPKIT\SETUP1 directory
- after Visual Basic version 3.0 for Windows shipped.
-
- Installation Notes
- ------------------
-
- Copy the files provided with this README.TXT file into you SETUPKIT\SETUP1
- directory.
-
- Distribution Notes
- ------------------
-
- You are free to distribute these files royalty free.
-
- Bug Fixes
- ---------
-
- The following are the features and bug fixes that were added to the
- SETUPKIT\SETUP1 files after Visual Basic version 3.0 for Windows was
- released. This file will be updated with the latest bug fixes and features
- any time a new post-release Visual Basic version 3.0 version of these
- files becomes available.
-
- Version Bug Comments
- ------- ------------------------------- -------------------------------------
- 1.00.001 SETUP1.EXE fails to copy the This problem occurs because the
- Visual Basic 3.0 version of file type of THREED.VBX changed
- THREED.VBX over the Visual from APP to DLL between Visual
- Basic 2.0 version of THREED.VBX. Basic versions 2.0 and 3.0.
- The CopyFile function in SETUP1.BAS
- was modified so that any file
- will be copied regardless of its
- type as long as the source file is
- the same or newer version compared
- to the destination file.
-
- 1.00.001 SETUP1.EXE fails when attempting A problem in the CreateProgManItem
- to show a Program Manager group when executing the ShowGroup DDE
- under Norton Desktop command causes SETUP1.EXE to fail
- under Norton Desktop. The syntax
- on the call to the ShowGroup DDE
- command was fixed to overcome this
- problem.
-
- 1.00.001 Unnecessary code included in SETUP1.FRM contains code that
- Form_Load event procedure of has been commented out and is
- SETUP1.FRM. not needed. This code was useful
- under the Visual Basic version 1.0
- of the Setup Toolkit.
- However, the features demonstrated
- by this code were removed from the
- Visual Basic version 2.0 and 3.0
- Setup Toolkit. This code has been
- removed.
-
- 1.00.001 Incorrect references to Messages containing references
- "Test Application" to "Test Application" were changed
- to reference the actual name of the
- application.
-
- 1.00.002 Setup Wizard is not able to Changes to the Setup Wizard version
- break large files > 1.2 meg 1.00.548 to fix this problem
- in size across multiple disks required changes to the
- CopyFile and ConcatSplitFiles routines
- in SETUP1.BAS.
-
- 1.00.002 A version number was added Check the general-declarations
- to a comment in the general section of SETUP1.FRM to determine
- -declarations section of the current version number of SETUP1.
- SETUP1.FRM.
-
- ------------------------------------------------------------------------------
- Below are the changes that were made to the CopyFile and ConcateSplitFiles
- routines in SETUP1.BAS
- ------------------------------------------------------------------------------
-
- OLD SETUP1 CODE:
- ----------------
- In Function CopyFile:
- If InFileVer$ <= OutFileVer$ Then
-
- In Sub ConcatSplitFiles:
- CopyLeftOver& = outfileLen& Mod 10
- CopyChunk# = (outfileLen& - CopyLeftOver&) / 10
- filevar$ = String$(CopyLeftOver&, 32)
- Get #fh2%, , filevar$
- Put #fh1%, , filevar$
- filevar$ = String$(CopyChunk#, 32)
- iFileMax% = 10
-
- NEW SETUP1 CODE:
- ----------------
- In Function CopyFile:
- If InFileVer$ <= OutFileVer$ And SourcePath <> DestinationPath Then
-
- In Sub ConcatSplitFiles:
- CopyLeftOver& = outfileLen& Mod 100
- CopyChunk# = (outfileLen& - CopyLeftOver&) / 100
- filevar$ = String$(CopyLeftOver&, 32)
- Get #fh2%, , filevar$
- Put #fh1%, , filevar$
- filevar$ = String$(CopyChunk#, 32)
- iFileMax% = 100
-